Tracing of loaded and dead cables, metal pipelines (depth up to 6 m, distance of 5 km from the generator connection place)
Tracing nonmetal pipelines by acoustic method.
Searching for leakages.
Searching for cable damages by acoustic and electromagnetic methods.
Selection of the cable from a bunch.
Detection of the pipeline depressurization places (depth 3 m).
Investigation of the ground before ground works.
Tracing of utility lines placed in channel or without channel by electromagnetic and acoustic methods.
The kit consists of the following devices:
Transmitter AG-144
Loop antenna IEM-301.2
Impact device «UM–112»
Headphones
Receiver АP-015
Connecting wires
Electromagnetic sensor EMD-230
Additional equipment
Acoustic sensor AD-215
Cable route detector with acoustic sensor:
Using the variable power transmitter AG-144 (7,5 W–180 W) and impact device “UM-112” (Unique!).
Complete absence of “parasitic” breakthrough on neighboring pipes.
High accuracy of location.
Acoustic method is used for tracing of metal and non-metal pipelines, especially under noise interference conditions when the electromagnetic localization is difficult to apply.
Cable route detector with electromagnetic sensor:
Using the variable power transmitter AG-144 (7,5 W–180 W) and impact device “UM-112” (Unique!).
Complete absence of “parasitic” breakthrough on neighboring pipes.
High accuracy of location.
Acoustic method is used for tracing of metal and non-metal pipelines, especially under noise interference conditions when the electromagnetic localization is difficult to apply.
Leak detector with acoustic sensor:
High sensitivity of acoustic sensor.
Technical parameters of the Receiver AP-015.
Parameters
Tracing
Leak detection
Operation (tracing / leak detection)
Determined by the connected sensor.
Central frequency of the filter receiver, Hz
Discrete 50/100/512/1024/8928
Frequency is regulated smoothly from 125 up to 2500
"Wide strip", Hz
40...10000
110...2900
Pre-filtering in the sensor amplifier
Switched resonance filter (50/100/512/1024/8928Hz, Q not more than 10)
Voltage 2...3,5 V, alkaline batteries, AA 1,5 V (2 pcs), accumulators AA 1.2V2,6 A/hour, upon the customer's requests, 2 pcs (work) + 2 pcs (storage) with 4 places charging device (from 220 V or 12V nets )
Maximum time of 2 accumulators charging not more than, hour
3
Minimum time of continuous work from a pair of accumulators, hour